UPS Systems: Product Families
An uninterruptible power supply keeps critical equipment running through a power interruption by drawing on batteries or another stored energy source until the utility returns or a generator starts. Line-interactive units regulate voltage and switch to battery when the input fails. Online double-conversion units rectify the incoming power and rebuild it through an inverter, so the load is always supplied from the inverter.
Rotary designs store energy in a spinning mass rather than only in batteries. Ratings that matter are kVA and kW, input and output voltage, phases, battery runtime and paralleling options. Buyers of surplus or replacement units ask by model series. The families below are grouped by those three designs.
37 product families from 8 manufacturers
Line-Interactive
Schneider Electric (APC)
Smart-UPS SMT
Listed as current
Single-phase line-interactive network UPS with pure sinewave output on battery.
- Rated range
- 750 VA to 3 kVA
Schneider Electric (APC)
Smart-UPS SMX
Listed as current
Line-interactive Smart-UPS with pure sinewave output and a higher power factor than SMT.
- Rated range
- 750 VA to 3 kVA
Schneider Electric (APC)
Smart-UPS SMC
Listed as current
Entry-level line-interactive Smart-UPS with simplified LCD and pure sinewave output.
- Rated range
- 1 kVA to 1.5 kVA
Schneider Electric (APC)
Smart-UPS SUM
Listed as current
Modular-design line-interactive Smart-UPS with hot-swappable modules.
- Rated range
- 1.5 kVA to 3 kVA
Schneider Electric (APC)
Smart-UPS SUA (4th generation)
Legacy
Older-generation line-interactive Smart-UPS, common on the used market.
- Rated range
- 700 VA to 5 kVA
Schneider Electric (APC)
Smart-UPS SU (3rd generation)
Legacy
Third-generation line-interactive Smart-UPS.
- Rated range
- 700 VA to 5 kVA
Schneider Electric (APC)
Smart-UPS SC
Legacy
Low-cost line-interactive Smart-UPS with step-approximated sinewave output.
- Rated range
- 420 VA to 1.5 kVA
Vertiv (Liebert)
Liebert PSI5
Listed as current
Line-interactive UPS with buck/boost AVR and pure sinewave on battery, in mini-tower, 1U rack and 2U rack/tower forms.
- Rated range
- 750 VA to 5000 VA; 120 V and 208 V input models
CyberPower
Smart App Sinewave (PR series)
Line-interactive pure-sinewave UPS with AVR and hot-swappable batteries.
- Rated range
- 1000 VA to 1500 VA on the series page (PR1000LCD, PR1500LCD)
Online (double-conversion)
Schneider Electric (APC)
Smart-UPS SRT (Smart-UPS On-Line)
Listed as current
Double-conversion online Smart-UPS, second generation, zero transfer time.
- Rated range
- 3 kVA to 10 kVA
Schneider Electric (APC)
Smart-UPS SURT
First-generation online Smart-UPS, double-conversion with zero transfer time.
- Rated range
- 1 kVA to 20 kVA
Schneider Electric (APC)
Symmetra PX
Modular, scalable three-phase UPS for data centers and facilities.
- Rated range
- 10-100 kW at 208 V; 100-500 kW at 480 V; 16-500 kW at 400 V
Schneider Electric (APC)
Galaxy VS
Listed as current
Modular three-phase UPS for edge and small/mid data centers.
- Rated range
- 20-150 kW at 480 V; 10-150 kW at 400 V; 10-75 kW at 208 V
Schneider Electric (APC)
Galaxy VL / VX / VXL
Listed as current
Higher-capacity three-phase Galaxy UPS ranges: VL 200-500 kW and 1600-2000 kW, VX 500-1500 kVA, VXL 500-1250 kW (480 V).
- Rated range
- 200 kW to 2000 kW class (per catalog listing)
Vertiv (Liebert)
Liebert GXT5
Listed as current
Single-phase online double-conversion UPS with pure sinewave and zero transfer time; rack/tower.
- Rated range
- 208 V models: 3 to 20 kVA
Vertiv (Liebert)
Liebert EXM
Listed as current
Transformer-free double-conversion UPS, modular, scalable and redundant configurations.
- Rated range
- 10-200 kVA/kW at 208 V; 30-250 kVA/kW at 480 V
Vertiv (Liebert)
Liebert EXL S1
Listed as current
Three-phase UPS with double-conversion and dynamic online modes, up to 8 units in parallel.
- Rated range
- 250-1200 kW/kVA, 480 V
Vertiv (Liebert)
Liebert NX (40-200 kVA)
DiscontinuedManufacturer names Liebert EXM as replacement
True online double-conversion three-phase UPS with SoftScale capacity growth.
- Rated range
- 40-200 kVA
Vertiv (Liebert)
Liebert NX (10-30 kVA)
DiscontinuedReplacement Liebert EXM
True online double-conversion three-phase UPS.
- Rated range
- 10-30 kVA
Vertiv (Liebert)
Liebert NX (225-600 kVA)
DiscontinuedReplacement Liebert EXL S1
Three-phase UPS with Eco mode, hot-rectifier operation and SoftScale upgrades.
- Rated range
- 225-600 kVA/kW
Vertiv (Liebert)
Liebert NXL
Discontinued
Three-phase high-power UPS listed with lithium-ion battery compatibility.
- Rated range
- 250-1100 kVA
Vertiv (Liebert)
Liebert Series 610
DiscontinuedReplacement Liebert NXL
Online three-phase UPS, an older large Liebert line.
- Rated range
- 225-1000 kVA on catalog page (manuals cover 100-1000 kVA)
Vertiv (Liebert)
Liebert Trinergy Cube
Legacy
Modular large UPS with hot-modular power cores and distributed batteries.
- Rated range
- Up to 1600 kW at 480 V (400 kVA core)
Mitsubishi Electric
9900AEGIS
Listed as current
Transformerless three-phase online double-conversion UPS with 3-level IGBT.
- Rated range
- 80, 100, 150, 160, 225 kVA at 480 V
Mitsubishi Electric
9900B
Listed as current
Three-phase online double-conversion UPS.
- Rated range
- 300-750 kVA/kW
Mitsubishi Electric
9900A
Earlier three-phase UPS module series, introduced to North America in 2008.
- Rated range
- Ratings not stated
Mitsubishi Electric
9800A
Older three-phase Mitsubishi UPS (sub-generations A to E).
- Rated range
- Ratings not stated
Mitsubishi Electric
2033 series (2033A/C/D/G)
Discontinued
Older 2033 UPS family, including 2033C in 10-20 and 30-50 kVA.
- Rated range
- 2033C listed as 10-20 kVA and 30-50 kVA
Mitsubishi Electric
1100A / 1100B / 7011B
Listed as current
Smaller online double-conversion Mitsubishi UPS: 7011B single-phase 6-12 kVA; 1100A 10-50 kVA; 1100B 50-80 kVA on the range page (lifecycle page states 10-80 kVA for each).
- Rated range
- 6-80 kVA overall
Mitsubishi Electric
9900CX / 9900D / SUMMIT
Listed as current
Large three-phase online double-conversion units: 9900CX 1050 kVA, 9900D 1200-2000 kVA (range page shows 1200-1250), SUMMIT 500-750 kVA silicon carbide.
- Rated range
- 500 kVA to 2000 kVA
Toshiba International
4400 Series
Monolithic three-phase double-conversion (VFI) UPS, all-IGBT, 208 V class.
- Rated range
- 15-50 kVA per the manufacturer page
CyberPower
Online series
Double-conversion online UPS, tower and rackmount, with ECO mode.
- Rated range
- 1000 VA to 10000 VA
Piller
Critical Power Module (CPM)
Static UPS with integrated flywheel energy storage, up to 8 in parallel. Not a rotary machine; listed under Online because it is a static design.
- Rated range
- 225 kW to 2.4 MW (300/360 kW modules)
Rotary
Piller
UNIBLOCK
Listed as current
Rotary UPS with electrically coupled technology; batteries or flywheel storage, air or water cooling.
- Rated range
- 150 kW to 50 MW, low and medium voltage
Piller
UB-V Series
Listed as current
Electrically coupled rotary UPS for data centers.
- Rated range
- 1100 kVA (1.0 MW) to 3600 kVA (3.24 MW), low or medium voltage
Hitec Power Protection
PowerPRO3600
Listed as current
Battery-free dynamic (rotary/flywheel) UPS with integrated standby generation.
- Rated range
- Up to 3600 kVA
Rolls-Royce mtu (formerly Kinolt / Euro-Diesel)
mtu Kinetic PowerPack
Listed as current
Dynamic UPS combining a flywheel energy store with a diesel engine and motor/generator, sold under the mtu brand since Feb 2021.
- Rated range
- Ratings not stated